Underwater Electromyographic Measurement Using a Waterproof Insulated Electrode

Article Properties
  • Language
    English
  • DOI (url)
  • Publication Date
    2012/01/01
  • Indian UGC (journal)
  • Refrences
    22
  • Citations
    8
  • Michiro OHTSU Master's program of Electrical and Electronic Engineering, Graduate School of Engineering, Tokyo Denki University
  • Yutaka FUKUOKA Department of Electrical Engineering, Kogakuin University
  • Akinori UENO Department of Electrical and Electronic Engineering, Tokyo Denki University
Cite
OHTSU, Michiro, et al. “Underwater Electromyographic Measurement Using a Waterproof Insulated Electrode”. Advanced Biomedical Engineering, vol. 1, 2012, pp. 81-88, https://doi.org/10.14326/abe.1.81.
OHTSU, M., FUKUOKA, Y., & UENO, A. (2012). Underwater Electromyographic Measurement Using a Waterproof Insulated Electrode. Advanced Biomedical Engineering, 1, 81-88. https://doi.org/10.14326/abe.1.81
OHTSU M, FUKUOKA Y, UENO A. Underwater Electromyographic Measurement Using a Waterproof Insulated Electrode. Advanced Biomedical Engineering. 2012;1:81-8.
Journal Categories
Medicine
Medicine (General)
Medical technology
Science
Biology (General)
Refrences
Title Journal Journal Categories Citations Publication Date
Surface EMG alterations induced by underwater recording Journal of Electromyography and Kinesiology
  • Medicine: Internal medicine: Neurosciences. Biological psychiatry. Neuropsychiatry
  • Science: Physiology
  • Medicine: Internal medicine: Special situations and conditions: Sports medicine
  • Geography. Anthropology. Recreation: Recreation. Leisure: Sports
  • Medicine: Surgery: Orthopedic surgery
  • Medicine: Internal medicine: Special situations and conditions: Sports medicine
  • Medicine: Medicine (General)
29 2004
Lower extremity muscle activity during deep-water running on self-determined pace Journal of Electromyography and Kinesiology
  • Medicine: Internal medicine: Neurosciences. Biological psychiatry. Neuropsychiatry
  • Science: Physiology
  • Medicine: Internal medicine: Special situations and conditions: Sports medicine
  • Geography. Anthropology. Recreation: Recreation. Leisure: Sports
  • Medicine: Surgery: Orthopedic surgery
  • Medicine: Internal medicine: Special situations and conditions: Sports medicine
  • Medicine: Medicine (General)
23 2008
A comparison of muscle activity and heart rate response during backward and forward walking on an underwater treadmill Gait & Posture
  • Medicine: Surgery: Orthopedic surgery
  • Medicine: Internal medicine: Special situations and conditions: Sports medicine
  • Medicine: Internal medicine: Neurosciences. Biological psychiatry. Neuropsychiatry
  • Medicine: Surgery: Orthopedic surgery
  • Geography. Anthropology. Recreation: Recreation. Leisure: Sports
  • Medicine: Medicine (General)
37 2007
Muscle activity and heart rate response during backward walking in water and on dry land European Journal of Applied Physiology
  • Science: Physiology
  • Geography. Anthropology. Recreation: Recreation. Leisure: Sports
  • Medicine: Medicine (General)
37 2004
Electromyographic Analysis of Walking in Water in Healthy Humans Journal of PHYSIOLOGICAL ANTHROPOLOGY and Applied Human Science 75 2004
Citations
Title Journal Journal Categories Citations Publication Date
Development of a Respiration and Cardiac Dynamics Waves Measurement System using Coupled Capacitance Electrode Advanced Biomedical Engineering
  • Medicine: Medicine (General): Medical technology
  • Science: Biology (General)
  • Medicine: Medicine (General): Medical technology
2023
A novel method for noninvasive bioelectric measurement utilizing conductivity of seawater

Scientific Reports
  • Medicine
  • Science
  • Science: Science (General)
2 2021
Water‐Resistant Conformal Hybrid Electrodes for Aquatic Endurable Electrocardiographic Monitoring

Advanced Materials
  • Science: Chemistry: General. Including alchemy
  • Science: Chemistry: Physical and theoretical chemistry
  • Technology: Chemical technology
  • Science: Chemistry
  • Science: Physics
  • Science: Physics
  • Technology: Electrical engineering. Electronics. Nuclear engineering: Materials of engineering and construction. Mechanics of materials
  • Technology: Electrical engineering. Electronics. Nuclear engineering: Materials of engineering and construction. Mechanics of materials
145 2020
An Insulated Flexible Sensor for Stable Electromyography Detection: Application to Prosthesis Control

Sensors
  • Technology: Chemical technology
  • Science: Chemistry: Analytical chemistry
  • Technology: Electrical engineering. Electronics. Nuclear engineering: Electric apparatus and materials. Electric circuits. Electric networks
  • Science: Mathematics: Instruments and machines
  • Science: Chemistry: Analytical chemistry
  • Science: Chemistry
22 2019
Spectral-Distance-Based Detection of EMG Activity From Capacitive Measurements IEEE Sensors Journal
  • Technology: Electrical engineering. Electronics. Nuclear engineering: Electric apparatus and materials. Electric circuits. Electric networks
  • Science: Mathematics: Instruments and machines
  • Science: Physics
  • Technology: Engineering (General). Civil engineering (General)
1 2018
Citations Analysis
The category Technology: Engineering (General). Civil engineering (General) 3 is the most commonly referenced area in studies that cite this article. The first research to cite this article was titled Integrated Circuits and Electrode Interfaces for Noninvasive Physiological Monitoring and was published in 2014. The most recent citation comes from a 2023 study titled Development of a Respiration and Cardiac Dynamics Waves Measurement System using Coupled Capacitance Electrode. This article reached its peak citation in 2017, with 2 citations. It has been cited in 8 different journals, 50% of which are open access. Among related journals, the Advanced Biomedical Engineering cited this research the most, with 1 citations. The chart below illustrates the annual citation trends for this article.
Citations used this article by year